Add to Cart
Non-Intelligent Diagnosis Detachable Probe IP67 NYSP-UK862 RF Admittance Level Switch
NYSP-UK862 RF Admittance Level Switch Working Principle
RF admittance material switch is based on theory of radio frequency admittance , modular designed with economical and practical advantages. It can be used to measure different mediums in various of conditions .
Both 24V and 220VAC power supply are optional , DPD 5A relay output, can control min equipment directly , the sensitivity and output delay can be adjusted by potentiometer at the field. Also can customize high temperature type.
NYSP-UK862 RF Admittance Level Switch Design Feature
1.RF admisttance material level switch consists of an electronic unit, an outside shell and a probe.
2.Main installation is top mounted and side mounted . Note : the shell of meter must be grounded reliably.
3.HCSP-30 supports separate installation, which can effectively avoid the influence of high temperature, strong earthquake, strong corrosion and toxic substances on the electronic units.
1.Strong versatility: it can measure liquid level and material level, also can meet the requirements of different temperature, pressure, mediums. Also can be used in corrosion, impact and other bad occasions.
2.Anti-hanging of material: the unique circuit design and sensor structure make its measurement free from the influence of the sensor hanging material, no need to clean regularly, and avoid mismeasurement.
3.Maintenance-free: no moving parts during measuring, no mechnical parts damage problem , no need regular maintenance.
4.Anti-interference: contact measurement, strong anti-interference ability, can overcome the influence of steam, foam and agitation.
5.Accurate and reliable: the measurement quantity is diversified, which makes the measurement more accurate. Not affected by environmental changes, with high stability and long service life.
NYSP-UK862 RF Admittance Level Switch Technical Parameters
Typical application | Level control of liquids, powders, granules and solids, especially for medium temperature applications |
Probe material | 304+PTFE (optional) |
Probe length | 500mm (can be customized upon request) |
Supply power | 220VAC,24VDC (optional) |
Process temperature | -184~+260℃ |
Process pressure | 0~2.0MPa |
Process connection | Thread, flange (optional) |
Signal output | DPDT output, 5A 24VDC or 5A 220VAC |
Time delay | 0-30s adjustment |
Failure alarm | Upper or lower limit, adjustable on site |
Protection level | IP67 |
Explosion-proof grade | Exia II CT6 (optional) |